Información del Producto

7 Model

7 Model

Covering the area used during reception and shipment to the facility protects the grain and the whole machine park against possible rain. In addition, an optional door is attached to its inlet and outlet, preventing dust from escaping during filling and discharging.
Special designs can be made in special sizes according to the equipment to be used in the Reception Building.

Cladding-Exterior Cladding
• Paint: Epoxy primer (Ral 7710) + Acrylic topcoat (Ral 7035) (Min80 μm)
• Hot Dip Galvanized EN ISO 1461
• Facade Cladding: Trapezoidal Sheet Ral9002-0.5mm

Material and Section Properties
• Horizontal and Cross Profiles; box, pipe profile
• Columns and Beams: HEA-HEB-IPE
• Material Quality
• Profile and Plate Materials: S235JR
• Column and Beam Materials: S275JR, S355JR

Earthquake Load
• TBDY 2018 (Turkish Building Earthquake Regulation)

Snow Load
• TS EN 1991-1-3 Eurocode 1: Snow loads

Wind Load
• TS EN 1991-1-4 Eurocode 1: Wind loads

Design Standards
• TBDY 2018 (Turkish Building Earthquake Regulation)
• TS 498 (Calculation value of the loads to be used in the dimensioning of the building elements)
• Design, Calculation and Construction Principles of Steel Structures (AISC-360-10)
• CYTHYE-2018: Design, Calculation and Construction Principles of Steel Structures